Expertise · Area

Fire sprinkler systems in Aljada 

Manolia Group provides fire sprinkler systems in Aljada, coordinating drawings and inspections with Sharjah Civil Defence and connections with Sharjah Electricity, Water & Gas Authority. Aljada is a large master-planned community being built near University City and the Emirates Road, with mid-rise apartments, townhouses, retail and leisure in phases since the late 2010s.

Fire sprinkler systems in Aljada: local context

Aljada is a large master-planned community being built near University City and the Emirates Road, with mid-rise apartments, townhouses, retail and leisure in phases since the late 2010s. It is one of Sharjah's biggest new developments and remains under active construction. The development combines residential neighbourhoods with retail, leisure and community buildings, delivered in phases by a single master developer, so infrastructure, utilities and access routes evolve as each phase is completed and handed over.

  • Phased community infrastructure means utility connections may be available at different times, so temporary power and testing arrangements are planned in advance.
  • Approvals typically start with a master developer NOC before Sharjah Municipality, Civil Defence and SEWA submissions.
  • Mid-rise buildings and townhouses typically use VRF or air-cooled chillers, with plant locations fixed by master plan guidelines on screening and noise.

Building types we serve in Aljada

For mid-rise residential and mixed-use buildings, the work concentrates on compact plant on the roof, car-park ventilation in podiums, metered apartment DBs and tight ceiling voids that make coordination drawings decisive.

Approvals and authorities in Aljada

Fire sprinkler systems in Aljada sits within Sharjah's regulatory framework. The authorities you will meet are:

  • Sharjah Civil Defence (SCD)
  • UAE Fire & Life Safety Code of Practice (UAE FLSC)
  • Sharjah Municipality (SM)
  • Sharjah Electricity, Water & Gas Authority (SEWA)

Scope of work

  • Preparation of sprinkler shop drawings showing head layout against reflected ceiling plans, beams, bulkheads, diffusers and light fittings, submitted for consultant and Civil Defence review.
  • Supply and installation of fire pump sets (electric duty, diesel standby and jockey pump), controllers, suction and delivery headers, test lines and flow-measuring arrangements.
  • Installation of risers, floor control valve assemblies with flow and tamper switches, drain and test stations, and zone isolation so floors can be serviced without shutting the building.
  • Hydrostatic pressure testing of every section, flushing of mains before head connection, and witnessed pump performance tests against the rated curve.

Systems we install

  • Fire water storage tanks with dedicated fire reserve and anti-vortex suction arrangement.
  • Electric, diesel and jockey fire pump packages with listed controllers and automatic transfer.

UAE site and climate challenges

  • Fire water tanks on roofs and in exposed pump rooms can reach high temperatures in summer, encouraging bacterial growth and corrosion. We specify insulated or shaded tanks, coated internals and ventilated pump rooms so stored water and diesel engines stay within manufacturer limits.
  • Unconditioned car parks and loading areas see large daily temperature swings and dust. Where the strategy calls for dry or pre-action systems, we protect compressors and valve trims from dust and plan drain points so condensate in the dry pipe is cleared during maintenance.
  • Grooved versus threaded pipework: grooved systems install faster and simplify future modification, while threaded small-bore branches suit tight ceiling voids; most projects use a combination by pipe size.

Relevant Manolia projects

AUS main & language buildings HVAC/BMS

University City (Sharjah) · HVAC & BMS · Completed

Design & build of HVAC and BMS renovation.

G+29 residential tower, Sharjah

Sharjah · MEP · Completed

Full MEP package for a 29-storey tower.

Frequently asked questions

Which authorities approve fire sprinkler systems in Aljada?

Approvals in Aljada typically involve Sharjah Civil Defence, UAE Fire & Life Safety Code of Practice, Sharjah Municipality and Sharjah Electricity, Water & Gas Authority. Exact routes depend on the plot, the master developer and whether the site sits in a free zone, so we confirm the authority matrix during mobilisation and prepare submissions accordingly.

Does Manolia work in Aljada?

Yes. Aljada is in Sharjah, roughly 20–60 minutes from central Dubai depending on traffic. Site teams are mobilised from our Dubai headquarters with supervision, QA/QC and HSE staff assigned to each project.

Why do sprinkler heads need to be coordinated with the ceiling?

Heads must sit at specific spacings and distances from walls, beams, diffusers and lights to discharge properly. If ceilings or MEP services shift after installation, heads may be obstructed or misaligned with tiles. Coordinated shop drawings and reflected ceiling plan checks avoid rework and inspection failures.

Next chapter

Tendering a building or MEP package?

Developers, main contractors and consultants: send drawings, BOQs or an RFQ to our engineering team. We review every enquiry and respond with a clear scope and programme.

Request a prequalification pack Send a project enquiry

WhatsApp